Soldier Pile Wall Example with DeepEX (English Units)
A soldier pile wall example will be analyzed with DeepEX. The following data is available:
a) Soil properties: Sand, friction angle = 30 degrees, total unit weight 120 pcf, loading modulus of elasticity Eload= 300 ksf, reloading modulus of elasticity Eur = 900 ksf. Ultimate bond resistance for ground anchors 40 psi.
b) Excavation depth: 23 ft, cantilever stage 10ft, ground anchor at 8ft depth at 15 degrees. Soldier piles spaced at 8ft off center. Include 600 psf traffic surcharge 1ft behind the wall for a length of 20ft.
Objective: Design the soldier pile and the ground achors with allowable stress methodology and obtain a wall embedment safety factor of 1.5.
New Example: Anchored Soldier Pile and Lagging Wall - Create and optimize in 5 minutes!
Figure: Model in DeepEX, Stage 3.
By double-clicking on the wall, we can define the wall section parameters through a user-friendly dialog. We simply have to select the wall type, choose the steel beam section we wish to use from the list and define pile spacing and lagging thichness and position.
Figure: Define wall type and soldier piles section.
Supports and loads can be added graphically on the model area, by using the Draw Loads and Draw Supports options in the General tab of DeepEX. After we draw the load or the support on the model, the Edit Options dialogs appear. There, we can define the load magnitude, the load position, the support position and structural section etc.
Figure: Define load and support properties.
DeepEX Features
All software features and capabilities! Review all available design methods and analysis standards!
DeepEX Upgrades
We continue our research and we introduce new unique features that extend the software capabilities!
New Examples
Review our latest, advanced shoring design examples for several wall types and support systems with DeepEX software!
In the Design tab of DeepEX, we can select to assign US allowable settings on this model for the structural design. This option will assign ACI for concrete and ASD code for steel design.
Figure: Assign US Allowable Settings for Concrete and Steel Design.
After the analysis is completed, the Analysis and Checking summary appears. There, we can review the maximum deflection, moment and shear values and the wall and support structural and geotechnical checks.
Figure: Analysis and Checking Summary.
Figure: Graphical results on model area (Wall Moment, Shear and Deflection diagrams).
DeepEx Demo
Structural and Geotechnical design of Deep Excavations.
Try the Full version for free and see how you can design and optimize any deep excavation model in the most efficient way!